Working range of the KU LNC 172212 C PRO is the frequency range 17200 to 21200 MHz. The standard IF range is 1000 to 2000 MHz. With four configurable oscillator frequencies the down converter can be used with different receivers easily. An additional user definable oscillator frequency caters for special requirements on the IF range. For more flexibility the gain of the down converter is adjustable in steps in 1dB. The possibility of connecting a 10 MHz reference source allows to ensure frequency stability for long-term applications. The KU LNC 172212 C PRO enclosed by rugged milled aluminium and features a waveguide input. The down converter is water resistant and ready for outdoor use.
No additional product downloads available.
Frequency range (RF) | 17200..21200 MHz |
Noise figure @ 18°C | typ. 2.5 dB, max. 3.0 dB |
Gain @ 25°C | typ. 55 dB |
Output IP3 | 20 dBm |
Maximum input power | 1 mW (0 dBm) |
LO accuracy @ 18°C | +/- 2 ppm |
LO frequency stability | +/- 3 ppm |
Supply voltage | +9 ... +36 V DC |
Current consumption | typ. 270 mA @ 12V |
Maximum case temperature | +55°C |
Weight | typ. 230 g |
Dimensions without connector (mm) | 82 x 64 x 24 |